New and Replacement Roof Linings
Roof Underlays or Underlinings
As a surveying practice, we are regularly asked to carry out Snagging Surveys of New Build properties and RICS Level 2 Surveys on nearly new properties that are still covered by a new-build warranty. We also get to inspect properties that have had their roofs replaced relatively recently, particularly if the homeowner is worried about a defect or deficiency.
One issue we encounter quite regularly is the incorrect installation of the roof underlining.
Why do roofs have underlinings?
Surprisingly, the surface layer of even a brand new tiled roof is unlikely to be completely watertight. Perhaps the most important role of most outer roof coverings is to provide protection from debris carried by the wind. A secondary benefit is that most outer roof coverings are also very good at resisting water penetration.
However, wind-driven rain, condensation, and water entering beneath displaced or damaged tiles could potentially enter the roof structure.
The roof underlining therefore provides a secondary line of defence. It is designed to catch water that penetrates the outer roof covering and direct it towards the eaves, where it can drain safely into the guttering.
A brief history of roof linings
Before the 1930’s roofs were built in such a way that the overlap of the slates or tiles was much greater (called “double lapping”) and a roof lining was essentially unnecessary.
However, in the housing boom of the 1930’s, with strong demand causing the price of building materials to increase, a way had to be found to reduce costs. This somewhat inevitably lead to the idea of reducing the overlap of the tiles and the need for a roof lining.
Made of hessian fibres soaked in bitumen, “sarking felt” was the original answer and was used almost continuously for about 60 years.
However, in the 1950’s, a cheaper solution was invented. Instead of hessian, “building paper” was used instead. This was only used for a few years because it became obvious fairly quickly that it was a substandard product prone to rapid deterioration.
Later iterations of sarking felt used a stronger string like weave due to the shallower pitch of the roofs. The tiles on these roofs needed to be protected from the transfer of wind loads from the lining below so a stiffer felt was needed.
In the late 1980s, a new plastic sheet style of roof lining was introduced. While robust, it severely limited ventilation within the roof void and caused significant condensation issues which in extreme circumstances caused degradation to the roof structure. Additional ventilation could be installed, but this was less than ideal and rarely solved the problem completely.
That brings us to modern semi-permeable “breathable fabric” roof linings. Originating in Germany in the early 1990’s, this type of roof lining started to become widely used in the UK just before the turn of the millennium.
What are modern roof liners made of?
Modern roof underlays are typically made from synthetic polypropylene based materials designed to resist water penetration. They tend to be “one-way” vapour-permeable which allows water vapour to pass out through the material while preventing liquid water from penetrating back in.
These breathable membranes can help manage moisture within the roof construction. However, additional ventilation may still be required, depending on the roof design and the membrane manufacturer’s recommendations.
Installation is key
Correct installation of these modern roof linings is essential to the long-term performance of the roof.
British Standard BS 5534: Slating and tiling for pitched roofs and vertical cladding – provides guidance on the design and installation of pitched roofs, including batten selection, methods of fixing, wind uplift formulas, a means of calculating fixing specifications, and the installation of the lining. It is also the baseline standard for Government accredited competency schemes like Competent Roofer. The image below is an idealised cutaway of the roof coverings and underlying structure for a modern roof.

Perhaps the most important thing is to ensure that the lining is installed with the correct side facing outwards. Otherwise, it would draw water into the roof space. Fortunately, the product manufacturers print logos on the outer surface so it’s pretty easy to get this right.
Next the membrane should be installed with the correct overlaps which depends upon location and wind exposure. The correct level of overlap ensures that the rainwater cannot be pushed far enough up the surface of the lining by the wind to penetrate into the roof space.
Finally, there needs to be a slight drape to the lining between each of the rafters to ensure that water does not collect on the outer surface of the lining next to the roof battens. This could cause wet-rot decay to the battens and/ or roof structure and could lead to condensation issues & mould growth within the roof space.
After several years of collating real world evidence, BS 5534 was updated in several areas to provide modern guidance on best building practice. Importantly, the new guidance concluded that the drape should nominally be 10mm with a maximum of 15mm to ensure that wind loads are not transferred to the outer roof covering.
Correct installation ensures that any water penetrating the outer roof covering and reaching the membrane can drain towards the eaves rather than collecting around the roof battens and fixings.
Why does this matter?
Where the membrane has been installed incorrectly, water may not drain as intended. Instead, it can collect around the battens and roof fixings, increasing the risk of water penetrating the membrane through nail holes or other vulnerable points.
Persistent moisture can increase the risk of timber decay and damage to the roof structure. Water penetration may also cause dampness within the roof space and, in some circumstances, lead to mould staining or leaks internally.
Incorrect installation may also invalidate the manufacturer’s warranty should problems arise.
The image below is of a roof that was approximately thirteen (13) years old. You can see alternating bands of white and black mould staining on the underlining caused by overtight installation. This allowed water to collect on the outer surface by the horizontal battens which in turn caused condensation on the inside surface that allowed the mould to grow.

The next photo is of a roof that is just five(5) years old and still covered by a New Build Warranty. During the construction of the building, the roofing contractor pulled the lining as tight as a drum skin. When the issue was brought to the developer’s attention, the roofing contractor went back to the property and retrofitted plastic ventilation grills. However, all that is likely to do is make the lining even tighter in places and accelerate the rate of decay of the lining and timber battens. A warranty claim was made.

The importance of getting it right
Roof underlay is an important but often overlooked component of a pitched roof. Although it is hidden beneath the roof coverings, its correct installation plays a significant role in directing rainwater to the gutters, managing moisture, and protecting the underlying roof structure.
Identifying installation defects at an early stage, particularly during a new-build snagging survey, can help homeowners address problems before they develop into more significant issues.
The image below was taken of a roof of a brand new property in the very final stages of construction immediately prior to exchange of contracts. The roof lining has been pulled so tight that it has “rucked up” in places which will almost certainly lead to the same problems seen in the photos above.

What to do now
If you are thinking of buying a brand new property then having a pre-purchase Snagging Report done prior to exchange of contracts will allow you to bring all defects to the attention of the property developer so that they can rectify them.
If you are thinking of buying a “nearly new” property that is still covered by a 10-year New Build Warranty Scheme (such as NHBC or Zurich) then an RICS Level 2 Survey will identify any defects with the property, including those which might be subject to a Warranty Claim.
If you have replaced your roof relatively recently and are concerned about any issues, then a Defect Diagnosis Report will provide you with a snapshot of the condition of the roof and list any defects with the installation.
And finally, if you are thinking of replacing your roof coverings in the immediate future, it would be a good idea to make sure that your roofing contractor is aware of all the required British Standards, including BS 5534 and the correct amount of drape to use between the rafters, to ensure that they get your roof installation right!